產品簡介
詳細介紹
6KVA/50KV油浸式試驗變壓器
技術參數:
| 容量 | 高壓電壓(KV) | 高壓電流(mA) | 低壓輸入 | 變比 | 溫升℃ | |||
(KVA) | AC | DC | AC | DC | 電壓(V) | 電流(A) | 高/儀 | 30分鐘 | |
YD 1.5/50 | 1.5 | 50 | 70 | 30 | 15 | 200 | 7.5 | 500 | 10 |
YD 3/50 | 3 | 50 | 70 | 60 | 15 | 200 | 15 | 500 | 10 |
YD 5/50 | 5 | 50 | 70 | 100 | 15 | 200 | 25 | 500 | 10 |
YD 10/50 | 10 | 50 | 70 | 200 | 50 | 200 | 50 | 500 | 10 |
YD 20/50 | 20 | 50 | 70 | 400 | 100 | 400 | 50 | 500 | 10 |
YD 30/50 | 30 | 50 | 70 | 600 | 100 | 400 | 75 | 500 | 10 |
YD 40/50 | 40 | 50 | 70 | 800 | 105 | 400 | 100 | 500 | 10 |
YD 50/50 | 50 | 50 | 70 | 1000 | 100 | 400 | 125 | 500 | 10 |
YD 10/100 | 10 | 100 | 140 | 100 | 50 | 400 | 25 | 1000 | 10 |
YD 20/100 | 20 | 100 | 140 | 200 | 100 | 400 | 50 | 1000 | 10 |
YD 30/100 | 30 | 100 | 140 | 300 | 100 | 400 | 75 | 1000 | 10 |
YD 40/100 | 40 | 100 | 140 | 400 | 100 | 400 | 100 | 1000 | 10 |
YD 50/100 | 50 | 100 | 140 | 500 | 100 | 400 | 125 | 1000 | 10 |
YD 20/100 | 20 | 150 | 210 | 133 | 100 | 400 | 50 | 1500 | 10 |
YD 30/100 | 30 | 150 | 210 | 200 | 100 | 400 | 75 | 1500 | 10 |
YD 40/100 | 40 | 150 | 210 | 267 | 100 | 400 | 100 | 1500 | 10 |
YD 50/100 | 50 | 150 | 210 | 333 | 100 | 400 | 125 | 1500 | 10 |
YD 100/150 | 100 | 150 | 210 | 667 | 150 | 400 | 250 | 1500 | 10 |
6KVA/50KV油浸式試驗變壓器
操作實驗辦法:
1、按上圖接線,審查壓力表批示外部氣體壓力能否一般(≥0.3MPA)
2、做交流耐壓時短路桿拔出孔J中,做直流走漏實驗,存入短路桿。
3、限流電阻設置裝備擺設:工頻耐壓每伏0.3~1歐:直流每伏5~10歐,正常試 驗可不必。
4、撤除被試品線引線,套管及器身臟污肅清,多余時采納屏障措施。
5、預備任務和保險措施停當,空試一次設備。
6、接上被試品,直流實驗使用屏障線,以排除雜散走漏。
7、合上電源,掌握箱(柜)電源指示綠燈亮。
8、按下起動旋鈕,起動批示燈亮。
9、對于掌握箱,逆時針勻稱加電,凝視電壓抒發到額外電壓值。
10、延續規則耐壓時間并凝視電流表批示。
11、耐壓時間到,凝視KV表,疾速勻稱降零。
12、做圖2試驗后用放電棒經電阻放電,而后直接接地放電。
13、高壓全體能夠被充洪水位置逐個放電后,改觀或者撤除高壓引線,及所有引線至此一次實驗停止。
上海百試電氣科技有限公司是電力檢測設備的優質制造商,通過ISO9001等專業機構認證。公司擁有專業的技術人員、*的制造設備和精密的檢測儀器,確保公司產品擁有行業的技術以及客戶信賴的質量,并為客戶提供的售前售后服務。公司產品獲得廣大的電力、化工、機械、礦業等用戶的*的好評,連續幾年評為優質電力檢測設備的供應商。
上海百試電氣科技有限公司是一家集科研開發、制造、銷售與一體的*。企業自成立以來一直以開拓創新的超前意識,敏銳獨到的市場觀念,穩扎穩打的務實精神,精心設計,潛心制作,細心把關,熱心服務,本著為廣大客戶服務的經商理念,將一如既往以“品質*、精誠服務、互利互惠、共同發展”為宗旨。